Gear Oil Pump with Oil Transfer Gear Pump
Products name: Gear Oil Pump with oil transfer gear pump Conditions of use: 1. KCB type gear oil pump for lubrication of;
Basic Info
Model NO. | KCB |
Certification | CE |
Series | KCB |
Transport Package | Wood Box |
Specification | CE |
Trademark | liansheng or OEM |
Origin | Shanghai, China |
HS Code | 84101330 |
Production Capacity | 50000 |
Product Description
Products name: Gear Oil Pump with oil transfer gear pump
Conditions of use:
1. KCB type gear oil pump for lubrication of a liquid conveying, the temperature is not higher than 70
celsius, for high temperature 200 celsius, with the units can be equipped with high temperature resistant
materials, viscosity of 5 × 10-5 ~ 1.5 × 10-3m2/S.
2. The pump is not suitable for conveying corrosive, containing hard particles or fibers, height volatile or
lightning low liquid, such as gasoline, stupid.
Product use:
1. Gear pumps are widely used in chemical, petroleum, metallurgy, light industry, synthetic fiber,
environmental protection, food, medicine and other departments.
2. This kind of product is stable and reliable performance, good sealing performance, handsome in
appearance, convenient operation and other advantages. In order to improve the product quality, reduce
the run, run, drip, leak, to prevent pollution, improve the environment, play a big role.
fault phenomenon | failure cause | elimination methods |
1.No power supply or one or two phase power supply is needed | Check all phases of power supply and restore power supply | |
2.Poor contact of ac contactor and burning of coil | Repair or replace contactors | |
can not start | 3. The power switch is not closed, malfunction or damaged | Close the switch and replace it if the power indicator does not turn on |
4. Thermal relay trip or damage | Check whether the motor is blocked, find out the reason and eliminate it.Manual reset is replaced if it cannot be started | |
Water level is too low | Put water in the sink | |
The motor burned | Repair or replace the motor | |
1.Line is loose | Check wiring and tighten connectors | |
2.Frequency converter malfunction | Check the fault content, check the cause according to the frequency converter manual, and restart after reset.Or disconnect the inverter power supply for a few seconds, the inverter fault reset before starting. | |
The manual is normal | 3The frequency converter is damaged | Repair or replace |
Automatic transmission failure | 4.Pressure switch damage | Repair or replace |
5The pressure transmitter is damaged | Repair or replace | |
6.Switch failure | Repair or replace | |
Pump non - suction pressure gauge pointer to beat violently | Insufficient water supply for perfusion, air leakage at the connection between pipeline and instrument | Check pipeline and bottom valve, refill water diversion. Tighten air leakage |
The pump consumes too much power | Too much flow, impeller wear | Check whether the pump shaft is bent, replace the impeller, close the outlet valve to reduce the flow |